85 Emjay Blvd
Brentwood, NY  11717
www.sleepyhollowchimneysupply.com
info@sleepyhollowchimneysupply.com
P: 1-800-553-5322   F: 1-631-231-2364

Home  |  Our Products  |  Contact Us  |  Find Us  |  Ordering 

 Suppliers to the Chimney Sweep, Flue &
Fireplace Restorations and Masonry
Heater Trades since 1978

 All of Sleepy Hollow's products
  carry a FULL LIFETIME WARRANTY!


Learn about Sleepy's "Print & Call" method
for safely ordering on the web. Trades Contact Us For Pricing!!

Check out
Sleepy's
book store
HERE

Count Rumfords Collected
Works Vol 2
Uncirculated
$65.00

 

PRODUCTS


Flexible Chimney Liners
Super-Flex®
Super-Flex® Light
Super-Flow

Rigid Chimney Liners
304-L Round & Oval
316-L Round & Oval
Cera Foil Thermal Insulation Blanket

Super Skin & Skin Clamps

Fittings & Components (round)
Tees
Elbows
Adapters
Storm Collars & Clamps
Rain Caps
Support Plates
Fireplace Re-line Baseplates


Fittings & Components (oval)
Tees
Adapters
Storm Collars & Clamps
Rain Caps
Support Plates
Fireplace Re-line Baseplates
Nose Cones

Selkirk

Dampers
Sleepy Hollow's Dampers
Lyemance Top-Lock I & II
Lyemance Top Sealing Damper
Energy Top and Energy Top Plus

Seal Tight Damper


Chimney Caps - Round
The Reverse Cone Cap
Rain and Enviro Class A Caps

Drip Cap
Super Turbine
Field Draft Inducer

Rain Caps -Square
Sleepy Hollow Punch Out
HYC
Gelco

Chimney Fans
Exhausto

Tjernlund

Chimney Housing
Sleepy Hollow Housing


Cleaning Tools & Equipment
Ace Brushes
Sleepy's Woodstock Brushes
Sleepy's Disc Brushes
Eva's Chimney Brushes
Hammer Head
Sleepy Hollow Rattan Rods
Sleepy Hollow Earth Rods
Brass Adaptors
Cleaning Tools  I
Cleaning Tools  II
Cleaning Supplies I
Cleaning Supplies II
Cleaning Supplies III

Installation Tools & Components
Super Winch
Screws & Fasteners
Hearth Stove Remover
Pro Shield
Cloths, Pads & Head Sock
Sundstrom
Bits & Chuck Drivers
Super and Furnace Cement

Super Chamber Parge
Chimney Saver
Barometric Dampers
Key Dampers
Bacharach Meter
Masonary Blades

Stove Gasketing
Condar Air Supply Ventilator
Sheet Metal Tools
Rivet Gun & Rivets
Center Peak Super Platform
Super Mix and Perlite
Refractory Foam

 

In-Line Draft Inducer Vertical Vent Systems For All Fuels

SOLVES VENTING PROBLEMS CAUSED BY
TYPICAL APPLICATIONS
draft inducer Undersized Chimneys draft inducer Boilers/Furnaces
draft inducer Negative Pressures draft inducer Water Heaters
draft inducer Long Horizontal Vent Connectors draft inducer Modular Boiler Systems
draft inducer Down Drafts draft inducer Multiple Appliances
draft inducer Cold Equipment Starts draft inducer Bakery Ovens
draft inducer Restrictive Heat Exchangers/Combustion chambers            draft inducer Factory Processes

Tjernlund In-Line Draft Inducers assure positive draft when restricted boilers and furnaces, poor chimneys or negative pressures in buildings prevent proper exhaust of combustion gases.  The venturi action starts air moving up the stack instantly & keeps it moving smoothly.  These units are quick and easy to install and completely automatic in operation.  In-Line Draft Inducers are built for long-lasting, trouble-free service and available in sizes and capacities to meet virtually all heating system requirements.  The Vari-Draft control permits adjustment to individual job requirements.

Vents/Chimneys utilizing In-Line Draft Inducers must be vertically terminated above the roof line.


 
EVERYTHING NEEDED TO CONFORM WITH NATIONAL MECHANICAL CODES
PS1505 Installation
Draft Inducer

Fan Prover Safety Interlock
Model PS1505
To satisfy national mechanical codes for oil and gas installations, Draft Inducers must be properly interlocked with burner circuits.  The PS1505 Fan Proving Switch monitors pressure within the Inducer housing to verify Inducer operation.  Used in conjunction with the UC1 Universal Control, it assures compliance with codes and simplifies electrical interlock with all 24/115 VAC burner circuits.  The PS1505 is not compatible with millivolt gas valves.
ACCESSORIES

The UC1 is a standardized control for Tjernlund Inducers/Venters.  It offers many installation, operational and safety benefits.
Universal Control
Model UC1
The UC1 can be interlocked with virtually any burner control circuit.  Features include: adjustable pre & post purge, LED status / diagnostic indicators, 10 second prover switch delay to avoid burner start up and wind induced short cycling.  Interlocks with any 24-120 VAC burner control circuit and also includes “dry” contact actuation option. Selectable voltage eliminates false activation by burner control circuits.  After each burner cycle the UC1 will continue to operate in post-purge mode to allow the Inducer/Venter to purge the heater and vent of residual flue gases.  A factory post-purge time is set at 2 minutes and is adjustable up to 16 minutes.
draft inducer
Multiple Appliance Controls
Models MAC1E, MAC4E
The MAC1E Multiple Appliance Control is used in conjunction with the UC1 Universal Control to easily interlock up to one additional 24 VAC, 115 VAC or millivolt controlled appliance.  It activates the Venter through its connections to the UC1 and in turn relies on the UC1 Fan Prover safety circuit (P1 & P2) to allow its interlocked appliances to operate.  Any pre/post-purge settings on the UC1 will be defaulted to the MAC1E. The MAC1E puts an end to difficult and costly job site wiring nightmares.  Circuit board housed in oversized 18 gauge electrical box with multiple knock-outs for easy wiring connections.

 

draft inducer
The MAC4E Multiple Appliance Control is used in conjunction with the UC1 Universal Control to easily interlock up to 4 additional 24 VAC, 115 VAC or millivolt controlled appliances.  It activates the Venter through its connections to the UC1 and in turn relies on the UC1 Fan Prover safety circuit (P1 & P2) to allow its interlocked appliances to operate.  Any pre/post-purge settings on the UC1 will be defaulted to the MAC4E. The MAC4E puts an end to difficult and costly job site wiring nightmares.  Circuit board housed in oversized 18 gauge electrical box with multiple knock-outs for easy wiring connections.

draft inducer


Millivolt Safety Interlock Kit
Model WHKE

For use with the UC1 Universal  Control, MAC1E or MAC4E auxiliary controls.  The WHKE gas pressure switch actuates the Inducer through the A-B dry contacts.  The Linear Limit switch disables the heater in the event of a venting malfunction.  Includes JA1 thermocouple junction adapter.  To interlock millivolt water heater(s) only with a UC1 controlled Inducer add a WHKE for each millivolt heater.  To interlock a millivolt water heater and one 24/115 VAC furnace or boiler with a UC1 controlled Inducer, add a WHKE and a MAC1E.
draft inducer

Barometric Draft Controls Models:
DC4, DC5, DC6, DC7, DC8, DC9, DC10
DC4G, DC6G, DC7G, DC8G, DC9G, DC10G

Quality engineered and manufactured to maintain a consistent draft on a wide range of oil and gas fired heating equipment.  May be used with chimney vented or power vented heating equipment.  For fan assisted gas, oil or solid fuel applications with vent diameters from 4"-10", choose the DC4 thru DC10.  For LP and natural gas applications with vent diameters from 4"-10", choose the DC4G thru DC10G.
draft inducer

MODEL SECTION TABLE AND ELECTRICAL DATA

draft inducer
IMPORTANT: Vents/Chimneys utilizing In-Line Draft Inducers must be vertically terminated above the roof line. Do not use for side wall venting. Consult factory for proper Gas or Oil Side Wall Vent options.  Tjernlund's Fixed & Variable Speed Specified Systems are also available with virtually unlimited capacities.

NOTE:
Inputs shown above are believed to be maximum capacities for inducers, when mounted on pipe sizes shown for ordinary jobs where a moderate amount of mechanical induced draft is required.

Consideration is given to typically higher static pressure requirements for larger installations, for the type of fuel burned, and for the type of draft control installed.

Some ratings may only be valid for extremely short vent lengths due to excessive pressure loss; i.e. the Model IL gas firing with draft hood in 10" pipe at 2,080,000 BTU/hr.

Where pressure requirements are unknown, or believed to be unusually severe, ask for complete performance curves or consult factory.

Draft Inducers should be installed in single wall vent pipe to assure proper performance.

MODEL DIMENSIONS
draft inducer


 


  Tjernlund, tjernlund in line draft inducer, tjernlund fans, chimney caps, chimney cap, chimney hats, chimney tops, chimney fans, Tjernlund In Line Draft Inducers, draft inducers, flue caps, tjernlund draft inducer, spark arrestors, rain caps, rain covers, fireplace, wood stove, draft, turbines, exhausto, chimney fan, tjernlund rooftop draft inducers, pizza oven fan, tjernlund chimney fans